Fans & Blowers
Sub-Menu
Axial Fans
TUBEAXIAL & SIDER PROPELLER FANS
Tubeaxial In-line Duct Fan

Direct Drive
- Axial fans
- Exhaust fan capacities up to 40,000 CFM in high static pressure applications up to 1/2″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- Drives are sized for a minimum 150% of drive horsepower
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Tubeaxial In-line Duct Fan

Belt Drive
- Rated up to 75,490 CFM in static pressure applications up to 1-1/2″ w.g.
- 12 sizes ranging from 12 to 60″ propeller diameters
- Motor and drives are located outside of the airstream
- Belt drives permit easy performance adjustments when needed
- Continuously welded and epoxy painted steel housing
- AMCA Air and Sound Licensed
- cULus Listed
Download Catalogue
Request Information
Sidewall Propeller Fans

Belt Drive
- Exhaust/Supply
- Exhaust air up to 40,000 CFM in high static pressure applications up to 1/2″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- Drives are sized for a minimum 150% of drive horsepower
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Sidewall Propeller Fans

Belt Drive
- Exhaust/Supply
- Exhaust air up to 47,000 CFM in high static pressure applications up to 3/4″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- Sized for minimum 150% of drive horsepower
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Sidewall Propeller Fans

Belt Drive
- Exhaust/Supply
- Exhaust air up to 85,000 CFM in high static pressure applications up to 1″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Sidewall Propeller Fans

Direct Drive
- Exhaust/Supply
- Exhaust air up to 55,000 CFM in high pressure applications up to 1″ w.g. 14 gauge galvanized steel panel, G-90 (sizes 54 to 60″)
- 16 gauge galvanized steel panel, G-90 (sizes 24 to 48″)
- Aluminum airfoil blades extruded or cast
- Available 2-speed units in select formats
- Suitable for all-angle installation
- AMCA Air and Sound Licensed
- UL Listed
- cULus 705 Listed
Download Catalogue
Request Information
ROOF TOP FANS
Upblast Propeller Roof Exhaust Fan

Belt Drive
- Exhaust/Supply
- Exhaust air up to 47,000 CFM in high static pressure applications up to 3/4″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- Sized for minimum 150% of drive horsepower
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Hooded Propeller Roof Supply Fans

Belt Drive
- Exhaust/Supply
- Exhaust air up to 85,000 CFM in high static pressure applications up to 1″ w.g.
- Heavy-gauge galvanized steel panel
- Die formed galvanized steel blades
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Hooded Propeller Roof Exhaust Fans

Direct Drive
- Exhaust/Supply
- Exhaust air up to 55,000 CFM in high pressure applications up to 1″ w.g. 14 gauge galvanized steel panel, G-90 (sizes 54 to 60″)
- 16 gauge galvanized steel panel, G-90 (sizes 24 to 48″)
- Aluminum airfoil blades extruded or cast
- Available 2-speed units in select formats
- Suitable for all-angle installation
- AMCA Air and Sound Licensed
- UL Listed
- cULus 705 Listed
Download Catalogue
Request Information
Remote Drive Upblast Propeller Roof Exhaust Fan

Belt Drive
- Exhaust air up to 52,000 CFM in static pressure applications up to 3/4″ w.g.
- Motor and drives are located outside of the exhaust airstream
- Suited for removal of heated or contaminated air
- Capable of continuous operation exhausting air up to 200°F
- Belt drives permit easy performance adjustments when needed
- cULus 705 Listed
Download Catalogue
Request Information
Remote Drive Upblast Propeller Fan for Heat & Smoke Removal

Belt Drive
- Exhaust air up to 52,000 CFM in static pressure applications up to 3/4″ w.g.
- Motor and drives are located outside of the exhaust airstream
- Designed and tested for emergency heat and smoke removal
- Successfully passed heat test of 1000°F for 15 minutes and 500°F for over 4 hours
- Belt drives permit easy performance adjustments when needed
- cULus 705 & 793 Listed
Download Catalogue
Request Information
Tubeaxial Upblast Propeller Roof Exhaust Fan

Direct Drive
- Exhaust air up to 60,116 CFM in static pressure applications up to 1″ w.g.
- Straight-through air flow design results in maximum exhaust efficiency
- Motor and drives are located outside of the exhaust airstream
- Belt drives permit easy performance adjustments when needed
- cULus 705 Listed
Download Catalogue
Request Information
Tubeaxial Upblast Propeller Fan for Heat and Smoke Removal

Belt Drive
- Exhaust air up to 57,000 CFM in static pressure applications up to 3/4″ w.g.
- Motor and drives are located outside of the exhaust airstream
- Designed and tested for emergency heat and smoke removal
- Successfully passed heat test of 1000⪚F for 15 minutes and 500°F for over 4 hours
- Belt drives permit easy performance adjustments when needed
- UL 793 Listed as Power Ventilator for Smoke Control Systems
Download Catalogue
Request Information
Upblast Propeller Roof Exhaust Fans

Belt Drive
- Exhaust air up to 78,000 CFM in static pressure applications up to 1/2″ w.g.
- Straight-through air flow design results in maximum exhaust efficiency
- Belt drives permit easy performance adjustments when needed
- Direct drive units have low sound levels and quiet operation
- cULus 705 Listed
Download Catalogue
Request Information
Upblast Propeller Roof Exhausters

Direct Drive
- Exhaust air up to 72,000 CFM in static pressure applications up to 1/2″ w.g.
- Straight-through air flow design results in maximum exhaust efficiency
- Motor and drives are located outside of the exhaust airstream
- Belt drives permit easy performance adjustments when needed
- cULus 705 Listed
Download Catalogue
Request Information
CENTRIFUGAL FANS
Airfoil Single Wide

Wheels have aerodynamically shaped blades providing non-overloading, highly efficient performance for relatively clean air applications.
- Airstream/performance: Clean air applications, medium to high volume and low to medium pressure applications.
- Applications: Supply fans, forced draft (FD), induced draft (ID) fans, exhaust fans, reverse air, dryer fans, cooling air, general ventilation, high temp applications.
- Sizes 18-1/4” – 89” wheel diameter
- AMCA Class 2, 3 & 4
- Volume up to 315,000 CFM
- Pressure up to 26″ WG
- Temperature Range -30° to 800°F
- Arrangement 1, 3, 4, 4V, 7, 8, 9
- IAT model AFSW
Download Catalogue
Request Information
Backward Inclined Single Wide

Wheels have flat, backwardly inclined, single thickness blades. Non-overloading high efficiency design generates low to moderate pressures.
- Airstream/Performance: Clean air to light dust loading, low to high volume and low to medium pressure.
- Applications: Supply fans, forced draft, dust collector, baghouse, bin vent, exhaust fans, combustion air, reverse air, dryer fans, kiln and flue gas recirculation, fume hood and spray booths, undergrate, cooling air, balancing fans, general ventilation, process, corrosive and high temp applications.
- Sizes 12-1/4” – 98-1/4” Wheel Diameter
- AMCA Class 2, 3, 4 & 5
- Volume up to 445,000 CFM
- Pressure up to 28″ WG
- Temperature Range -30° to 800°F
- Arrangement 1, 3, 4, 4V, 7, 8, 9
- IAT Model BISW
Download Catalogue
Request Information
Pressure Blower

Shrouded optimized bladed design offers efficient and stable performance over a wide range of pressure and volume requirements. Inlet and outlet flanges are round for easy standard pipe duct connections.
- Airstream/Performance: Clean air to light duty dust loading, low to medium volume, medium to high pressure applications.
- Applications: Supply and exhaust fans, combustion air, distribution air, reverse air, cooler fans, pneumatic conveying, dust collector/baghouse exhaust fans, flue gas recirculation, general ventilation, process, corrosive and high temp applications.
- Sizes 14″ – 26″ Wheel Diameter
- Construction Class 60
- Volume Up to 10,250 CFM
- Pressure Up to 66″ WG
- Temperature Range -30° to 600°F
- Arrangement 1, 4, 4V, 8, 9, 10
- IAT Model PB
Download Catalogue
Request Information
General Purpose Backward Inclined

Economical, modular design allows for short lead times and a competitive price while offering similar performance to our BISW line up to AMCA Class 3.
- Airstream/performance: Clean air to light dust loading, low to high volume and low to medium pressure applications.
- Applications: Supply fans, forced draft, dust collector, baghouse, bin vent, exhaust fans, combustion air, reverse air, dryer fans, fume hood and spray booths, cooling air, balancing fans, general ventilation, process, corrosive and high temp applications.
- Sizes 12-1/4” – 36” Wheel Diameter
- AMCA Class 1, 2 & 3
- Volume up to 47,000 CFM
- Pressure up to 18.5″ WG
- Temperature Range -30° to 600°F
- Arrangement 1, 4, 4V, 8, 9, 10
- IAT Model GPBI
Download Catalogue
Request Information
(Radial Blade) Industrial Exhauster

Wheel with flat radial blades and flat back plate design prevent stringy or fibrous material from hanging up and wrapping around the blades, and are used for light to medium material handling applications.
- Airstream/performance: Radial open (paddle wheel), clean air to heavy material loading, low to high volume, low to medium pressure applications.
- Applications: Scrubber, cyclone fans, relay or booster fans, pneumatic conveying, classifier fans, material conveying fans, truck loading, chip fans, corrosive and high temp gas streams
- Sizes 12-1/4” – 57-1/2” wheel diameter
- Construction Class 15, 30 & 50
- Volume up to 92,000 CFM
- Pressure up to 45″ WG
- Temperature Range -30° to 1000°F
- Arrangement 1, 4, 4V, 8, 9
- IAT Model IRF
Download Catalogue
Request Information
(Paddle Wheel) Industrial Exhauster

Paddle wheel design centrifugal fans used for material handling applications where moderate pressure and CFM are required.
- Airstream/Performance: Radial open (paddle wheel), clean air to heavy material loading, low to high volume, low to medium pressure applications.
- Applications: Scrubber, cyclone fans, relay or booster fans, pneumatic conveying, classifier fans, material conveying fans, truck loading, chip fans, corrosive and high temp gas streams.
- Sizes 12-1/4” – 85-1/4” wheel diameter
- Construction Class 15, 30 & 50
- Volume up to 200,000 CFM
- Pressure up to 50″ WG
- Temperature Range -30° to 1000°F
- Arrangement 1, 8, 9 industrial fan
- IAT Model IRO
Download Catalogue
Request Information
SPUN ALUMINUM CENTRIFUGAL FANS
Downblast Direct Drive Centrifugal Roof Exhaust Fans

- Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2″ w.g.
- Attractive spun aluminum exterior
- Direct drive units have low sound levels and quiet operation
- Curved non-overloading backward inclined wheel for efficiency at higher static pressures
- AMCA Air and Sound Licensed
- cULus 705 Listed
- EcoWatt® (SDBDe Models ONLY)
Download Catalogue
Request Information
Belt Drive Centrifugal Downblast Roof Exhaust Fan

- Exhaust air up to 15,583 CFM in high static pressure applications up to 1-3/4″ w.g.
- Attractive spun aluminum exterior roof fan
- Belt drives of the exhaust fan permit easy performance adjustments when needed
- Curved non-overloading backward inclined wheel for efficiency at higher static pressures
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Upblast Direct Drive Centrifugal Roof/Sidewall Exhaust Fans

- Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2″ w.g.
- Attractive spun aluminum exterior
- Direct drive units have low sound levels and quiet operation
- Curved non-overloading backward inclined wheel for efficiency at higher static pressures
- Roof or sidewall mounting options
- AMCA Air and Sound Licensed
- cULus 705 or 762 Listed
- Ecowatt® (STXDe & STXDe-RHUL Models ONLY)
Download Catalogue
Request Information
Upblast Belt Drive Centrifugal Roof/Sidewall Exhaust Fans

Direct Drive
- Exhaust air up to 8,648 CFM in high static pressure applications up to 2-3/4″ w.g.
- Attractive spun aluminum exterior
- Belt drives permit easy performance adjustments when needed
- Curved non-overloading backward inclined wheel for efficiency at higher static pressures
- Drives are sized for a minimum 150% of drive horsepower
- AMCA Air and Sound Licensed
- cULus 705 or 762 Listed
Download Catalogue
Request Information
Downblast Belt Drive Centrifugal Roof Exhaust Fan

Belt Drive
- Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4″ w.g.
- Attractive spun aluminum exterior
- Belt drives permit easy performance adjustments when needed
- Non-overloading backward inclined wheel for efficiency at higher static pressures
- AMCA Air and Sound Licensed
- cULus 705 Listed
Download Catalogue
Request Information
Upblast Belt Drive Centrifugal Roof Exhaust Fans

Belt Drive
- Exhaust air up to 35,000 CFM in high static pressure applications up to 3-1/4″ w.g.
- Attractive spun aluminum exterior
- Belt drives permit easy performance adjustments when needed
- Non-overloading backward inclined wheel for efficiency at higher static pressures
- Roof or sidewall mounting options
- AMCA Air and Sound Licensed
- cULus 705 or 762 Listed
- NFPA – suitable for National Fire Protection Association Installations
Download Catalogue
Request Information
Centaxia uses a variety of quality products produced by a number of established North American manufacturers. Please contact us for specific details for your application.